CONTEC CMS7000 Multi-Parameter Medical Patient Monitor for ICU/ Hospital/ Clinics with CE/ FDA
Â
Â
Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
This medical patient monitor has other abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc.
Â
Â
1- 12.1'' TFT color LCD, 15-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakhstan, Polish, Czech).
2- Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
3- All-round medical patient monitor for adult, pediatric and neonates.
4- With the standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe.
5- Waveform, parameter color and location can be set optionally.
6- Operation mode: keys and buttons.
7- Display up to 8-channel waveform on one screen.
8- Display 7-lead ECG waveform on one screen, and with ECG step function.
9- Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
10- HRV analysis function.
11- NIBP measurement mode-Manual/AUTO/Continuous, storage for 4800-group NIBP data.
12- Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
13- Drug concentration calculation and titration table functions.
14- Print trend table data with one key.
15- Connect to Central Monitoring System by 3G, WiFi, or wired mode.
16- AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
17- Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).
Â
Â
â—‹ ECG
Lead mode | 3-lead or 5-lead |
Lead selection | I, II, III, aVR, aVL, aVF, V |
Waveform | 5-lead, 2-channel |
3-lead, 1-channel | |
Gain | 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV |
Scan speed | 12.5mm/s, 25 mm/s, 50 mm/s |
HR | |
Measurement and alarm range | 15~350bpm |
Accuracy | ±1% or ±1bpm, whichever is greater |
Alarm accuracy | ± 2 bpm |
Resolution | 1 bpm |
ST-segment monitoring | |
Measurement and alarm range | -2.0mV~+2.0mV |
Accuracy | -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is greater |
Other range | Unspecified |
Arrhythmia analysis | ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC |
Pacemaker | yes |
Â
â—‹ RESPIRATION
Method | R-F(RA-LL) Impedance |
Respiration rate | |
Measurement and alarm range | 0~150rpm |
Resolution | 1 rpm |
Measurement accuracy | ±2 rpm |
Alarm accuracy | ±3 rpm |
Apnea alarm | 10~40s |
Scan speed | 6.25 mm/s, 12.5 mm/s, 25 mm/s |
Â
â—‹ NIBP
Method | Oscillometry |
Mode | Manual/AUTO/Continuous |
Measurement interval in AUTO mode | 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes |
Measurement period in Continuous mode | 5 minutes |
Measurement and alarm range | 10 ~ 270 mmHg |
Resolution | 1 mmHg |
Cuff pressure accuracy | ±3 mmHg |
Measurement accuracy | |
Maximal mean deviation | ±5 mmHg |
Maximal standard deviation | 8mmHg |
Over-pressure protection | |
Adult mode | 297±3 mmHg |
Pediatric mode | 240±3 mmHg |
Neonatal mode | 147±3 mmHg |
Â
â—‹ SpO2
Measurement and alarm range | 0 ~ 100% |
Resolution | 1% |
Measurement accuracy | 70%~100%: ±2% |
0%~69%: unspecified |
Â
â—‹ PR
Measurement and alarm range | 30 ~ 250 bpm |
Measurement accuracy | ±2 bpm or ±2%, whichever is greater |
Â
â—‹ TEMP
Channel | Dual-channel |
Measurement and alarm range | 0 ~ 50℃ |
Resolution | 0.1 ℃ |
Accuracy | ±0.1 ℃ |
Â
â—‹ EtCO2
Method | Sidestream or Mainstream |
Measurement range for CO2 | 0~150mmHg |
Resolution for CO2 | 0 ~ 69 mmHg: 0.1 mmHg |
70 ~ 150 mmHg: 0.25 mmHg | |
Accuracy for CO2 | 0 ~ 40 mmHg: ±2 mmHg |
41 ~ 70 mmHg: ±5% | |
71 ~ 100 mmHg: ±8% | |
101 ~ 150 mmHg: ±10% | |
AwRR range | 2~150 rpm |
AwRR accuracy | ±1 rpm |
Apnea alarm | Yes |
Â
â—‹ IBP
Channel | Dual-channel |
Label | ART, PA, CVP, RAP, LAP, ICP, P1, P2 |
Measurement and alarm range | -10~300 mmHg |
Resolution | 1 mmHg |
Accuracy | ±2% or 1mmHg, whichever is greater |
Power supply | AC 100-240V, 50/60Hz |
Safety classification | Class I, type CF defibrillation-proof applied part |
Â
Â
â— Adult fingertip SpO2 probe (5-pin);
â— Adult NIBP cuff;
â— NIBP extension tube;
â— ECG lead cable;
â— ECG electrode;
â— Temperature probe;
â— Power cord;
â— User Manual.
◠Physical characteristic: 319 mm(L) × 161 mm(W) × 269 mm(H); Weight: 3.6 Kg.
Â
Â
Â
Â
Our products have been certificated by CE, FDA and COS/VIOS certificate. If you are interested in our medical patient monitor, send your detail inquirement to us!